Passive Fire Protection
Passive fire protection is an integral part of building construction and helps to gain valuable time in the event of a fire.
In our role as an accredited testing laboratory in accordance with DIN EN ISO/IEC 17025 (Accreditation No. D-PL 17819-01-00), we offer all types of testing procedures in the field of passive fire protection. With a strong commitment to quality assurance and extensive expertise in product testing, we set standards for precision, reliability, and compliance.
Our many years of experience and in-depth technical knowledge enable us to test, classify, and certify a comprehensive range of products in accordance with stringent national and European standards. In doing so, we contribute to ensuring product safety, performance, and environmental compatibility.
- As an EU-certified testing body for reaction to fire and fire resistance in accordance with the Construction Products Regulation No. 305/2011
- Our services include recognized testing, inspection, and certification in line with national building regulations, with a particular focus on the behavior of construction products when exposed to external fire.
Participation in Standardization Committees and Panels
- Active member of Sector Group SH02 Fire Protection within the Fire Sector Group (FSG)
- Active member of EGOLF (European Group of Organisations for Fire Testing, Inspection and Certification)
- Participation in the expert committee “Fire Protection for Cable Installation Systems” at DIBt
- Participation in the standardization committee CEN/TC 263/WG 2
- Participation in the standardization committee NA 005-52-23 AA “Reaction to Fire of Facade Cladding Systems”
- Participation in the standardization committee NA 087-00-14 AA
- Participation in the DKE standardization committee K 213 “Firefighting in Electrical Installations”
Contact us!
Fill out the contact form to receive information about Kiwa’s services or to request a customized quotation.
Specialized Analysis of Polymeric Building Materials and Plastics

Performance test of battery cells in cycles

Testing of curtain walls, cladding and structural sealant glazing

Testing of road equipment: Circulation fixtures

Wooden beam ceiling: Measurement of impact sound reduction on lightweight construction ceilings according to ISO 10140-3

Environmental Testing

Battery testing according to UN 38.3

Analysis of blister formation in coatings

Investigation of Steel Bridge Coatings Used by Deutsche Bahn - Corrosion Protection - DBS 918084

Vehicle-to-Grid (V2G) certification for grid integration

Acoustics tests and sound insulation(8)
Roof coverings, roof lights, roof windows, and ancillary products(2)

Heat Pump Testing

Watermark for Australia by Kiwa

Wind-uplift test of roof constructions

WRAS Testing and Approval

Non-destructive testing

Certification of vulcanised rubber products for cold & hot non-drinking water applications -BRL 2013

Inspection structural safety of buildings

Concrete repair planning and construction supervision
